ISO certified unit in India that manufactures of Strainer
Precision multi-stage Oil Filtration Systems achieve and maintain ISO 4406 cleanliness codes as tight as 14/12/9 — the standard demanded by high-pressure servo-hydraulic and turbine control systems — using validated Beta-ratio filtration rather than nominal micron-rating guesswork.
Engineering & Working Principle
Oil is drawn through progressive filtration stages (typically 10-5-3 micron absolute), with each stage rated by its Beta ratio ( Beta (x) > 200 per ISO 16889 multi-pass test) rather than nominal rating alone, guaranteeing actual particle capture efficiency of >99.5% at the rated micron size. Differential pressure transmitters trigger element-change alarms before bypass occurs.
Technical Specifications
Standards Compliance
ISO 4406, ISO 16889 (multi-pass test), NAS 1638 (aerospace/hydraulic equivalents)
Key Features
Applications
Servo-hydraulic systems, steam and gas turbine lube/control oil, precision gearboxes, and high-pressure hydraulic power units.
Why It Outperforms Standard Systems
Most filtration systems are specified by nominal micron rating alone — a marketing number, not a performance guarantee. Ours are specified by validated Beta ratio per ISO 16889, the same rigor used by aerospace-hydraulic and turbine-control OEMs.
Benefits
Beta ratio (?x), tested per ISO 16889 multi-pass method, is the ratio of upstream to downstream particle counts at a given micron size — a ?200 rating guarantees 99.5% capture efficiency at that size, unlike a nominal micron rating which is only an estimate.
Servo-hydraulic and precision turbine control systems typically require ISO 4406 14/12/9; general industrial hydraulic systems are often fine at 18/16/13 — we size the filtration stages specifically to your required code.
Yes — duplex, switchable filter housings allow you to divert flow to a standby filter chamber while replacing elements in the other, with zero interruption to oil supply.
Mineral oils, synthetic oils, phosphate-ester fire-resistant fluids, and most industrial hydraulic and lubricating oils are all compatible — housing seals and media are selected based on your specific fluid type.
Inline laser particle counters can be integrated to provide continuous, real-time ISO 4406 cleanliness code readings, rather than relying on periodic manual sampling alone.